When AGC is set to OFF, the RF gain control can be adjusted.
4-2 ATTENUATOR / RF AMPLIFIER
Activating the attenuator reduces signal to the RF input stages of the AR5001D in order to prevent
overloading due to connection to an external antenna or when the receiver is used close to strong
transmissions.
The AR5001D has 5 settings for the attenuator, 0 dB (AMP), 0 dB, -10 dB, -20 dB, and AUTO.
To change the parameter setting, press the [ATT] key.
Select a new attenuator parameter from the list by rotating the sub dial. To accept the new parameter,
press the [MHz] key.
4-3 RF GAIN
Press the [FUNC] key, and press the [6] key to activate the manual RF gain control.
To change the RF gain manually, rotate the squelch knob. To cancel the manual RF gain control,
repeat above steps.
Note: The manual RF gain control is not available while the receiver selects AGC mode.
4-4 ANTENNA INPUT
The AR5001D has two antenna input ports. However, a total of four antennas can be used with