AOR AR2700 Manuel d'utilisateur Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
- 4 -
Connection & commands
(4) Connection for RS232 operation
The connection and setup parameters are identical to those for the AR8000 receiver... for this reason please
refer to page 6 section 4 of the main CU8232 operating manual.
Sections 5, 6 & 7 refer to the main CU8232 manual
(8) Revised list of commands (AR2700)
Application Command
VFO Freq Input RF
Receiver Function AT AU MC MD RX ST
SQ, S-Meter LC LM MG SG
Receive Mode MR MG MS SG SS VF
Search BN BQ BS SE SG SR SS TP
Search Data Write AT AU MD SE SL SU ST
Pass Freq PD PR PS PW
Memo CH, Scan BM BN MA MG ML MP MQ MR MS
Memo CH Data Write AT AU MD MX RF ST
Others EX SC SI TI QP RR
é[UP] (1E) ê[DOWN] (1F) ( )= Hex Decimal
Arrow is a control code of ASCII.
No delimiter is required when sending Arrow.
Commands which have dual roles are duplicated in this list.
(9) Command index (AR2700)
AT Register the attenuator position ON/OFF.
AU Register the auto mode ON/OFF.
BM Register the scan bank link ON/OFF.
BN Change the search/scan bank.
BQ Register the search bank link function ON/OFF.
BS Register the search bank link ON/OFF.
EX End the Remote mode (RS232C).
LC Respond with the received freq and S-level when SQ opens.
LM Respond with the S-level reading and SQ open/close.
MA Respond with the contents of the present bank or specified bank.
MC Select the monitor switch position.
MD Select the receive mode.
MG Start the scan mode. Respond with receive freq and S-level reading when
SQ is open (as LC).
ML Register the scan bank link function ON/OFF.
MP Register the present memory channel as Pass channel.
MQ Delete the present bank or memory channel.
MR Switch to the memory read (M.RE) mode.
MS Switch to the scan (SCAN) mode.
MX Write data into memory channel.
PD Delete the Search Pass Freq
PR Recall the Search Pass Freq
PS Register the Search Pass Freq
PU Register the pause (free search / scan) On / Off
PW Register the presently receiving freq as Pass Freq
QP Turn the power switch Off
RF Key in the Freq in VFO
RR Control the AR2700 record / play back
RX Respond with the presently receiving data
SC Change the operating code of the option unit (when fitted - not available in the UK).
SE Register the Search data.
SG Start the Search mode. Respond with freq and S-level reading when SQ is open.
SI Switch the option unit ON/OFF (when fitted - not available in the UK).
SL Write the start freq of Search.
SR Recall the Search data.
SS Start the Search.
ST Register the step size in search mode.