- 14 -
The command SGx[ï] causes an automatic response and searching from the specified bank
where x = 0 ~ 9.
Related commands LC MG SS é ê
SI
Set code for option ON / OFF (not available in the UK).
The SI command is used to review and select the optional code unit On / Off if the option is fitted to the
AR2700.
To review the current status use the command SI[ï]
The response will be in the format SIn
where
n = 0 Optional code unit OFF
n = 1 Optional code unit ON
To switch the code option ON / OFF use the format SIn[ï]
where
SI0[ï] = Optional code unit OFF
SI1[ï] = Optional code unit ON
Related command SC
SL
Set the lower frequency of a search bank.
This command cannot be used on its' own but must be used in conjunction with the SE command, please
refer to the section on SE.
SL Lower frequency limit nnnnnnnnm0 (Hz)
or
nnnn.nnnnm (MHz)
m = "0" or "5" (tens of Hz position), "5" is only used when the step size is 6.25 kHz. Any entry other
than "0" or "5" will be ignored.
Related commands SE SL SU TT
SR
Recall search data.
The SR command is used to recall search data for a chosen bank.
To recall the search data from the currently selected search bank use the format
SR[ï]
To recall the search data from a specific bank use the format SRx[ï]
where x = search bank 0 ~ 9.
A typical response may be: SRC_SL0118500000_SU0135900000_ST025000_AU1_MD2_AT0
This is a data breakdown of:
Search bank C
Lower (start) frequency 118.50 MHz
Upper (end) frequency 135.90 MHz
Automode ON (this means that mode & step are ignored so
do not have to be specified as will be taken
from the receivers preprogrammed data)
Attenuator OFF
Related command SE
SI SL SR