AOR SDU-5000 Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Récepteur AOR SDU-5000. AOR SDU-5000 Instruction manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - SDU5600

SDU5600 PROFESSIONAL SPECTRUM DISPLAY UNIT FOR USE WITH A COMPANION RECEIVER INSTRUCTION MANUAL AOR, LTD. Downloaded byAmateur Radio D

Page 2 - TABLE OF CONTENTS

9 (1) CF Center Frequency The frequency at the center of the screen is always indicated in MHz, and the highest resolu

Page 3 - 1-3 Power requirements

10 (10) Receiver Information This section indicates the status of the connected receiver with the following items:

Page 4 - 1-5 Features

11 Note: The measuring modes (Spectrum Analyzer mode, Step Resolution Mode, Channel Scope Mode), frequency span, tuning step, marke

Page 5 - 2 Controls and functions

12 (Note: This function is available only when the receiver model is set to [Othe

Page 6

13 The three (3) of the right column of the Main Control

Page 7 - 2-2 Rear panel

14 In the Spectrum Analyzer mode, the receive frequency is equal to the center frequency of the screen. In the Spectrum Analyzer mode or the Step R

Page 8 - 3 Connection to a receiver

15 On the above screen, the following information is displayed. Receive marker: 81.3 MHz

Page 9 - 4 Switch on the SDU5600…

16 The followings are the features of respective mode. • Spectrum Analyzer Mode (SPECT) The standard default mode used

Page 10

17 6-6 Basic Settings for Operation 6-6-1 Spectrum Analyzer Mode On the above screen, the following information is displayed.

Page 11 - 5-3 Default Mode

18 Press the [SPAN/STEP] key located between the LCD display and the rotary dial encoder. The icon indicating the current span frequency will be re

Page 12 - 6 Settings

1 TABLE OF CONTENTS 1 Index ------------------------------------------------------------------------------------------------ 1 1-1

Page 13 - 6-3 Receiver Settings

19 Center frequency (CF): 122.5 MHz Display step: 25 KHz

Page 14

20 Enter the Start Frequency and the End (Stop) Frequency using the Special Function Keys located on the lower side of the LCD display and the numer

Page 15 -

21 Using the numeric keypad, enter a new frequency followed by the [ENT] key ([KHz] key or [MHz] key.) Step Frequency (Ch. STEP) Press the [Ch. ST

Page 16 - 6-5 Operation Modes

22 Press the [AMPLITUDE] [ 2 ] [MHz] key. [Caution] Compare the following 2 screen shots.

Page 17

23 Resolution Band Width (RBW) The resolution is selectable from 4 KHz, 32 KHz, 64 KHz, and 128 KHz. Greater detail

Page 18

24 The first one has 4 KHz of RBW and the second has 128 KHz of RBW settings. Greater detail is obtained by narrow RBW, however, you can get fas

Page 19

25 • Marker In the normal spectrum analyzer mode, the rotary dial encoder may be used to move the marker position indicated by a vertical b

Page 20

26 • Continuous Peak (C-Peak) When the Continuous Peak function is activated, the marker automatically hops to the largest new signal once a sw

Page 21

27 In the Spectrum Analyzer mode or the Step Resolution mode, pressing the [MK.F] key on the numeric keypad will set the marker frequency to the rec

Page 22

28 Press the [CLR] key to exit from this function. 6-8-3 Middle Trace (MED) Press the [FUNC] key and press the [9] key

Page 23 - [Caution]

2 1-1 Introduction Thank you for purchasing the SDU5600 Spectrum Display Unit. For many years, AOR has been marketing the world’s first color spec

Page 24

29 To activate the Waterfall Function, press the [FUNC] key and press the [ . ] (decimal) key on the numeric keys.

Page 25 - 6-7 Marker Function

30 In this chapter, we learn how to use the SDU5600 with the AR5000 receiver. Before proceeding, please review Connection to a Re

Page 26

31 ( Note: The following functions of the AR5000 can be controlled from the SDU5600. Receive Frequency

Page 27

32 Changing the Resolution Band Width (RBW) (from 4 KHz  128 KHz) • Press the [RBW] key on the numeric keypad. • Rotate the R

Page 28 - 6-8 Calculation Function

33 7-4 Monitoring VHF Air Band in the Channel Scope Mode Let’s try to monitor VHF Air Band in the Channel Scope Mode. • To go into the Channel

Page 29 - 6-9 Waterfall Function

34 7-5 Operation Mode Summary The following is a summary of the operation mode of the SDU5600. A proper mode should be select

Page 30 - 7 Getting Started

35 While monitoring a crowded band with lots of strong signals, the noise floor of the SDU5600 may rise due to the AGC action of the re

Page 31

36 10 Specifications Model: SDU5600 Input Frequency:

Page 32

37 temperature extremes or water, including rainfall or immersion. 4. Exposure to toxic materials, biohazards, radioactive materials or other cont

Page 33

38 AOR, LTD. 2-6-4, Misuji, Taitok-Ku Tokyo, 111-0055, Japan http://www.aorja.com AOR USA, INC. 20655 S. Western Ave. Suite 112 To

Page 34

3 Should the SDU5600 appear to behave strangely, normal operation may easily be resumed by resetting the microprocessor. Simply power off the SDU560

Page 35 - 8 Special Considerations

4 2 Controls and functions 2-1 Front panel controls The front panel of the SDU5600 is dominated by the large color LCD. Controls are ‘grouped’ to

Page 36

5 2 LCD (Liquid Crystal Display) 5 inch TFT color display graphics 3 Special function keys Three special function keys are located un

Page 37 - 12 LIMITED WARRANTY

6 6. Special keys Three (3) special keys are provided with the SDU5600. Those keys are to be used for entry of center frequency, fr

Page 38 - Amateur Radio Directory

7 4. DC 12 V Connect the supplied AC adapter to this connector. If you wish to operate with 12 V external regulated power supply, it s

Page 39

8 Receiver menu Model number Remarks =============================================

Commentaires sur ces manuels

Pas de commentaire